1. Identificação | |
Tipo de Referência | Artigo em Revista Científica (Journal Article) |
Site | mtc-m21c.sid.inpe.br |
Código do Detentor | isadg {BR SPINPE} ibi 8JMKD3MGPCW/3DT298S |
Identificador | 8JMKD3MGP3W34R/4383S9P |
Repositório | sid.inpe.br/mtc-m21c/2020/09.09.11.32 |
Última Atualização | 2020:09.09.11.32.41 (UTC) simone |
Repositório de Metadados | sid.inpe.br/mtc-m21c/2020/09.09.11.32.41 |
Última Atualização dos Metadados | 2021:03.02.19.16.51 (UTC) administrator |
DOI | {10.5028/jatm.2011. 03032511} |
ISSN | 1984-9648 |
Chave de Citação | FerroYamPimNacSab:2011:LiRiWa |
Título | Lightning risk warnings based on atmospheric electric field measurements in Brazil |
Ano | 2011 |
Mês | Sept. |
Data de Acesso | 04 maio 2024 |
Tipo de Trabalho | journal article |
Tipo Secundário | PRE PN |
Número de Arquivos | 1 |
Tamanho | 2389 KiB |
|
2. Contextualização | |
Autor | 1 Ferro, Marco Antonio da Silva 2 Yamasaki, Jorge 3 Pimentel, Douglas Roberto M. 4 Naccarato, Kleber Pinheiro 5 Saba, Marcelo Magalhães Fares |
Grupo | 1 2 3 4 DGE-CEA-INPE-MCT-BR 5 CST-CST-INPE-MCT-BR |
Afiliação | 1 Instituto de Aeronáutica e Espaço (IAE) 2 Instituto de Aeronáutica e Espaço (IAE) 3 Instituto de Aeronáutica e Espaço (IAE) 4 Instituto Nacional de Pesquisas Espaciais (INPE) 5 Instituto Nacional de Pesquisas Espaciais (INPE) |
Endereço de e-Mail do Autor | 1 marcomasf@iae.cta.br 2 yamasakijy@iae.cta.br 3 douglas.roberto.fis@gmail.com 4 kleberp@dge.inpe.br 5 msaba@dge.inpe.br |
Revista | Journal of Aerospace Technology and Management |
Volume | 3 |
Número | 3 |
Páginas | 301-310 |
Histórico (UTC) | 2020-09-09 11:32:41 :: simone -> administrator :: 2020-09-09 11:32:42 :: administrator -> simone :: 2011 2020-09-09 11:33:15 :: simone -> administrator :: 2011 2021-03-02 19:16:51 :: administrator -> simone :: 2011 |
|
3. Conteúdo e estrutura | |
É a matriz ou uma cópia? | é a matriz |
Estágio do Conteúdo | concluido |
Transferível | 1 |
Tipo do Conteúdo | External Contribution |
Tipo de Versão | publisher |
Palavras-Chave | Atmospheric electric field Electric field-mill Lightning |
Resumo | This paper presents a methodology that employs the electrostatic field variations caused by thundercloud formation or displacement to generate lightning warnings over a region of interest in Southeastern Brazil. These warnings can be used to prevent accidents during hazardous operations, such as the manufacturing, loading, and test of motor-rockets. In these cases, certain equipment may be moved into covered facilities and personnel are required to take shelter. It is also possible to avoid the threat of natural and triggered lightning to launches. The atmospheric electric field database, including the summer seasons of 2007/2008 and 2008/2009 (from November to February), and, for the same period and region, the cloud-to-ground lightning data provided by the Brazilian lightning detection network BrasilDAT were used in order to perform a comparative analysis between the lightning warnings and the cloud-to-ground lightning strikes that effectively occurred inside the area of concern. The analysis was done for three areas surrounding the sensor installation defined as circles with 5, 10 and 15 km of radius to determine the most effective detection range. For each area it was done using several critical electric field thresholds: +/- 0.5; +/- 0.8; +/- 0.9; +/- 1.0; +/- 1.2; and +/- 1.5 kV/m. As a result of the reduction of atmospheric electric field data provided by the sensor installed in area of concern and lightning provided by BrasilDAT, it was possible, for each of the areas of alert proposals, to obtain the following parameters: the number of effective alarms; the number of false alarms; and the number of failure to warning. From the analysis of these parameters, it was possible to conclude that, apparently, the most interesting critical electric field threshold to be used is the level of 0.9 kV/m in association with a distance range of 10 km around the point where the sensor is installed. |
Área | CEA |
Arranjo 1 | urlib.net > BDMCI > Fonds > Produção anterior à 2021 > DIDGE > Lightning risk warnings... |
Arranjo 2 | urlib.net > COCST > Lightning risk warnings... |
Conteúdo da Pasta doc | acessar |
Conteúdo da Pasta source | não têm arquivos |
Conteúdo da Pasta agreement | |
|
4. Condições de acesso e uso | |
URL dos dados | http://urlib.net/ibi/8JMKD3MGP3W34R/4383S9P |
URL dos dados zipados | http://urlib.net/zip/8JMKD3MGP3W34R/4383S9P |
Idioma | en |
Arquivo Alvo | 2011 A - JATM Lightning_risk_warnings_based_on_atmospheric_electric_field_measurements_in_brazil.pdf |
Grupo de Usuários | simone |
Grupo de Leitores | administrator simone |
Visibilidade | shown |
Política de Arquivamento | allowpublisher allowfinaldraft |
Permissão de Atualização | não transferida |
|
5. Fontes relacionadas | |
Repositório Espelho | urlib.net/www/2017/11.22.19.04.03 |
Unidades Imediatamente Superiores | 8JMKD3MGPCW/3EU29DP 8JMKD3MGPCW/3F3T29H |
Lista de Itens Citando | sid.inpe.br/bibdigital/2013/10.19.20.40 3 sid.inpe.br/bibdigital/2013/10.01.22.11 2 |
Divulgação | PORTALCAPES; COMPENDEX. |
Acervo Hospedeiro | urlib.net/www/2017/11.22.19.04 |
|
6. Notas | |
Campos Vazios | alternatejournal archivist callnumber copyholder copyright creatorhistory descriptionlevel e-mailaddress format isbn label lineage mark nextedition notes orcid parameterlist parentrepositories previousedition previouslowerunit progress project readpermission resumeid rightsholder schedulinginformation secondarydate secondarykey secondarymark session shorttitle sponsor subject tertiarymark tertiarytype url |
|
7. Controle da descrição | |
e-Mail (login) | simone |
atualizar | |
|